UFX-210 Atomic Absorption Spectrophotometer (AAS)
FITUR:
Teknik analisis nyala udara-asetilena oksigen Kaya yang inovatif
T ia dipatenkan teknik analisis api mengadopsi kaya oksigen api udara-asetilen sebagai substitusi untuk nitrous oxide-acetylene api untuk analisis elemen suhu tinggi, seperti Ca, Al, Ba, W, Mo, Ti, V, dll api suhu secara terus menerus dapat disesuaikan antara 2300-2950 ℃ , yang memungkinkan untuk memilih suhu atomisasi terbaik untuk berbagai elemen. Ini fitur pengoperasian yang mudah, biaya analisis rendah dan jangkauan analitik AAS nyala lebar. Nyala oksigen yang kaya tidak akan mencemari lingkungan dan tidak berbahaya bagi tubuh manusia. Ini adalah terobosan dalam analisis AAS nyala.
Sistem atomisasi tungku api / grafit terpadu, dapat diganti dengan burner emisi api
Sistem kontrol otomatis yang akurat
Analisis tungku grafit sepenuhnya otomatis yang andal
Langkah-langkah perlindungan keamanan yang sempurna
Desain elektronik yang canggih dan andal
Perangkat lunak analisis yang mudah dan praktis
Perbandingan
Massa Karakteristik Beberapa Elemen menggunakan api oksigen kaya-C 2 H 2 dan metode nyala lainnya
Unit: ug / ml
Element |
Wavelength (nm) |
Rich oxygen air-C2H2 flame |
N2O-C2H2 flame |
Air-C2H2 flame |
Ca |
422.7 |
0.009 |
0.05 |
0.07 |
Yb |
378.8 |
0.037 |
0.08 |
7.6 |
Eu |
459.4 |
0.137 |
0.3 |
3.0 |
Al |
309.3 |
0.4 |
0.7 |
|
Sr |
460.7 |
0.016 |
0.1 |
0.15 |
Ba |
553.5 |
0.1 |
0.4 |
10.0 |
Mo |
313.3 |
0.15 |
0.4 |
0.8 |
W |
255.1 |
3.2 |
5.0 |
|
Ga |
287.4 |
0.4 |
1.0 |
1.3 |
Sm |
429.7 |
2.92 |
8.5 |
|
La |
550.1 |
37.2 |
35.0 |
|
Sn |
224.6 |
0.8 |
3.0 |
50 |
SPESIFIKASI:
Main Specification |
Wavelength range |
190-900nm |
Wavelength accuracy |
Better than ±0.25nm |
|
Resolution |
Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. |
|
Baseline stability |
0.004A/30min |
|
Background correction |
The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times. |
|
Light Source System |
Lamp turret |
Motorized 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.) |
Lamp current adjustment |
Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA. |
|
Lamp power supply mode |
400Hz square wave pulse; 100Hz narrow square wave pulse + 400Hz wide square pulse wave. |
|
Optical System |
Monochomator |
Single beam, Czerny-Turner design grating monochromator |
Grating |
1800 l/mm |
|
Focal length |
277mm |
|
Blazed Wavelength |
250nm |
|
Spectral Bandwidth |
0.1nm, 0.2nm, 0.4nm, 1.2nm, auto switch over |
|
Flame Atomizer |
Burner |
10cm single slot all-titanium burner |
Spray chamber |
Corrosion resistant all-plastic spray chamber. |
|
Nebulizer |
High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7mL/min |
|
Emission burner provided |
||
Graphite Furnace |
Temperature range |
Room temperature~3000ºC |
Heating rate |
2000℃/s |
|
Graphite tube dimensions |
28mm (L) x 8mm (OD) |
|
Characteristic mass |
Cd≤0.8 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g |
|
Precision |
Cd≤3%, Cu≤3%, Mo≤4% |
|
Detection and Data Processing System |
Detector |
R928 photomultiplier with high sensitivity and wide spectral range. |
Software |
Under Windows operating system |
|
Analytical method |
Working curve auto-fitting; standard addition method; automatic sensitivity correction; automatic calculation of concentration and content. |
|
Repeat times |
1~99 times, automatic calculation of mean value, standard deviation and relative standard deviation. |
|
Multi-task Functions |
Sequential determination of multi-elements in the same sample. |
|
Condition reading |
With model function |
|
Result printing |
Measurement data and final analytical report printout, editing with Excel. |
|
Standard RS-232 serial port communication |
||
Graphite Furnace Autosampler |
Sample tray capacity |
55 sample vessels and 5 reagent vessels |
Vessel material |
Polypropylene |
|
Vessel volume |
3ml for sample vessel, 20ml for reagent vessel |
|
Minimum sampling volume |
1μl |
|
Repeatable sampling times |
1~99 times |
|
Sampling system |
Accurate dual pump system, with 100μl and 1ml injectors. |
|
Characteristic Concentration and Detection Limit |
Air-C2H2 flame Rich oxygen Air-C2H2 flame |
Cu: Characteristic concentration ≤ 0.025 mg/L, Detection limit≤0.006mg/L; Ba: Characteristic concentration ≤ 0.22mg/L Al: Characteristic concentration ≤ 0.4mg/L |
Function Expansion |
Hydride vapor generator can be connected for hydride analysis. |
|
Dimensions and Weight |
Main unit |
107×49×58cm, 140kg |
Graphite furnace |
42×42×46cm, 65kg |
|
Autosampler |
40×29×29cm, 15kg |
Kategori Produk : Peralatan laboratorium > Spektrofotometer
Beranda > Produk > Peralatan laboratorium > Spektrofotometer > UFX-210 Atomic Absorption Spectrophotometer (AAS)
Kirim permintaan
Mr. Frank
Email:
Kirim permintaanMobile Site
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.